20
Vol. 66, No. 3 2015
Northeast Florida Medicine
Endovascular Neurosurgery
References
1. Ransohoff J: A case of aortic aneurism treated by the
insertion of wire.
JAMA
7:481-485,1886.
2. Siddique K, Alvernia J, Fraser K, LanzinoG. Treatment
of aneurysms with wires and electricity: a historical over-
view.
J Neurosurg
99 1102-1107, 2003.
3. Duncan J. On the galvano-puncture of aneurisms.
Edinb
Med J
11:920-933,1866.
4. Ligon, LB. History and Developments in Imaging
Techniques: Egas Moniz and Angiography. Seminars
in Pediatric Diseases, Vol 14, No 2 (April) 2003:
pp173-181.
5. Doby, T. Cerebral Angiography and Egas Moniz AJR
159:364, Aug 1992.
6. Lima A. Egas Moniz 1874-1955; Surg Neurol 1973
1(2):247–248
7. Dagi TF. Neurosurgery and the introduction of cerebral
angiography. Neurosurg Clin N Am 2001;12(1):145–
53, ix 35.
8. Dámasio AR. Egas Moniz, pioneer of angiography and
leucotomy. Mt Sinai J Med 1975;42(6):502–13.
9. Vitek JJ, Smith MJ. The myth of the Brooks method
of embolization: a brief history of the endovascular
treatment of carotid-cavernous sinus fistula.
J Neurointerv
Surg.
2009 Dec;1(2):108-11.
10. Werner SC BA, King BG. Aneurysm of the internal
carotid artery within the skull: wiring and electrothermic
coagulation.
JAMA
116:578, 1941.
11. Luessenhop AJ, Spence WT. Artificial embolization of
cerebral arteries. Report of use in a case of arteriove-
nous malformation. J Am Med Assoc.1960 Mar 12;
172:1153-5.
12. Higgs CZJ, Macafee DAL, et.al: The seldinger Technique
50 years on. Lancet vol.366; issue 9494 15-21 Oct. 2005:
1407-1409.
13. Seldinger SI (1953). Catheter replacement of the needle
in percutaneous arteriography; a new technique Acta
radiologica 39 (5): 368–76.
14. Kessler L, Wholey M: Internal Carotid Occlusion for
Treatment of Intracranial Aneurysms. Radiology 95: 581-
583, June 1970.
15. Serbinenko FA. Balloon catheterization and occlu-
sion of major cerebral vessels.
J Neurosurg.
1974 Aug;
41(2):125-45.
16. Kerber C. Balloon catheter with a calibrated leak. A new
system for superselective angiography and occlusive cath-
eter therapy. Radiology 120:547-550 Sept 1976.
17. Kerber CW, Bank WO, Cromwell LD. Calibrated leak
balloon microcatheter: a device for arterial exploration
and occlusive therapy.
AJR Am J Roentgenol.
1979 Feb;
132(2):207-12.
18. Higashida R, Halbach VV, Barnwell SL, et.al. Treatment
of intracranial aneurysms with preservation of the parent
vessel: results of percutaneous balloon embolization in 84
patients.
AJNR Am J Neuroradiol
11:633-640, 1990.
19. Engleson E. Catheter for guide wire tracking. US Patent
No. 4739768, 1986.
20. Guglielmi G. History of the genesis of detachable coils J
Neurosurg Vol 111:1-8 July 2009.
21. Gugliemi G, Vinuela F, Dion J, Duckweiler G: Electro-
thrombosis of Saccular Aneurysms via an Endovascualr
ApproachPart 2: Preliminary Clinical Experience. Special
Article. J Neurosurg 75:8-14,1991.
22. Moret J, Cognard C, Weill A, et al. Reconstruction tech-
nic in the treatment of wide-neck intracranial aneurysms.
Long-term angiographic and clinical results. A propos of
56 cases.
J Neuroradiol.
1997;24:30–44.
23. Biondi A, Janardhan V, Katz JM, et. al. Neuroform stent
assisted coil embolization of wide neck intracranial aneu-
rysms: strategies in stent deployment and midterm follow
up. Neurosurgery 2007; 61:460-8.
24. Kallmes D, Ding H, Dai D, Kardirval D, Lewis D, and
Cloft H. A new endoluminal, flow-disrupting device
for treatment of saccular aneurysms. Stroke, vol.38, no.8
pp.2346-2352, 2007.
25. Nelson P, Lylyk P, Szikora I, et.al. The Pipeline emboli-
zation device for the intracranial treatment of aneurysms
trial, American Journal of Neuroradiology, vol.32,no. 1,
pp.34-40, 2011.
26. Becske C, Kallmes D, Saatci I, et. a.l. Pipeline for
uncoilable or failed aneurysms: results from the multi-
center clinical trial, Radiology, vol. 267, no. 3, pp.858-
868, 2013.